Controller, Relay, Interfaces
Street Light Controller
Wireless Components
Sensors
One of the core strengths of the zencontrol light management solution is the comprehensive range of sensors, meeting any requirements of your project.
Indoor
Outdoor
Wall Mount PIR IP44/IP65, 12m
Wall Mount Microwave IP44/IP65, 12m
Batten Microwave IP65, 12m
Outdoor Street Light
Sensor Accessories
Sensor Mounting Kits
Sensor Adaptors
Commissioning Control
Switches
zencontrol provides a wide range of highly customizable DALI-2 switches for any possible application and design and rich in features and functions
Smart Drivers and Plug-Ins
Room Control
With the innovative features built into every room controller, building lighting control is easier, simpler and reduces installation risk. The below comparisons are made between zencontrol Room controller and other manufacturers DALI gateways. Times are based on the commissioning job by an agent/ engineer and not the installation by the electrician.

,Zencontrol – next Generation Light Management
The Room controller represents a significant paradigm shift within lighting control. Building upon traditional LCM and DALI Gateways, the Room controller makes a generational jump.
Full featured and controllable
Out of the box, the Room controller is designed to work, however, a commissioning agent can tailor the product to work for almost any custom requirement.

Room setup
Time taken to setup a full DALI line with 10 rooms, 2 switches / room and 2 sensors / room in absence or presence mode

Addressing
Time to address and arrange a full DALI line.

1’000 Changes
Time to make 1’000 changes on a DALI line, including connecting/ getting the current value and writing value

Replace / Repair
Time to setup a single DALI fitting after failure, including adding to group and allowing switch and sensor control.
Fixed Loads? No Problem!
Every channel on the Room controller can be toggled to act as a fully compliant DALI relay. This relay can be used to control other non-DALI loads, seamlessly integrating their control with other DALI products. The Room controller will automatically detect non-DALI loads and automatically set them up associating the control to the previous channel.


Commissioning errors sorted
Issues associated with duplicate DALI addresses, which can be caused when relocating fittings, pre-addressed devices or poorly designed products are automatically fixed with zencontrol. The original device will retain its address while the newly added device will be moved to the next free location, reducing the time spent fault finding.

Simple setup
The Room controller groups and sets up the rooms automatically, allowing the lighting, switches and sensors to work out of the box. Switches and sensors can work in absence or presence, with time outs of 10 / 15 / 25 / 30 minutes, without a commissioning agent. Throughout its entire lifespan, any additional or replaced products will also be addressed, grouped and setup automatically reducing downtime and expensive call out fees.

Automatic addressing
No more running around, zencontrol products address DALI devices automatically and is complete before you even need it. Add additional fittings at any time knowing they will be addressed and added to the system.

Wiring
With the zencontrol Room controller, wiring becomes simpler and easier. Compared to traditional LCM wiring, less custom lead lengths are required making installation for the luminaire manufacturer and the installer easier. For each room simply connect all light fittings, sensors, switches and emergency lighting together and back into a single channel on the Room controller.
Wiring the Room controller could not be easier.
The zencontrol Room controller advantage
Control systems take a long time to set up and commission, the solution: zencontrol does all the hard parts. Save time, money and reduce risk with the automatic setup features in zencontrol products. Our smart controllers make light work of the tasks which burden installers.
Task
Random addressing of luminaires
Scanning settings from luminaires, switches and sensors
Readdressing new devices
Fixing address conflict
Setup of switches and sensors
Grouping of Rooms
Syncing data changes made by the installer / users
Conservative Systems
5…10⁺ mins per 64 fittings
2…10 mins per 64 fittings
2…10 mins per 64 fittings
2⁺ mins per fitting
2⁺ mins per fitting
5…10⁺ mins per group
1…10⁺ mins dependent on text

Automatic
Automatic
Automatic
Automatic
Automatic
Automatic
Automatic
Logical Numbering, automatic
The Room controller makes your job easier by sequentially numbering all devices found in a room, even after you add more devices. Sequential numbering makes the process of commissioning and fault finding easier.


Build to Integrate
A modern building requires many building services to be connected. zencontrol makes integration easy with several supported methods:
▪ RS232 connections
▪ Modbus over IP
▪ BACnet over IP (server)
▪ Volt free I/O (low level triggers)
▪ Cloud based API
▪ KNX over IP
Additionally, as BACnet, Modbus and KNX support is at the application controller level, no additional controller between the lighting control system and BMS is required. This reduces cost, increases speed and removes the risk of a single point failure.
Shorts
Shorts can happen: the DALI ballast or drivers can short the DALI line or poor wiring or setup can lead to a DALI line short. Finding a DALI short is a timely process which can sometimes leave the lights uncontrollable for some time.
The zencontrol room controller is able to identify the room in which a short is present and isolate it from the rest of the DALI line. This significantly reduces the fault-finding time and leaves all other rooms operational.

Sensors
Zencontrol has a range of sensors and adaptors covering any needs a project might have. The smart design is allowing the use of the zencontrol sensors in combination with any other DALI-2 sensors and products on one DALI-2 bus
Smart Control
With practically unlimited control, sensors can be configured to perform almost any task. Absence and presence modes are easily selectable, with fully configurable timeouts, actions and modes.


Standard
Smart sensors which connect to the DALI line directly, offering PIR, lux and colour

Expandable
Use zencontrol’s mains converter to connect mains rated sensors to DALI

Built-in sensors
Connect a mains-rated sensor to any zencontrol smart driver to enable a full DALI sensor

Feature packed
zencontrol standard sensors are powered directly from the DALI bus and have inbuilt PIR, lux and colour sensors. With zencontrol technology; lux, movement and colour (including CRI) can be logged back to the Cloud to be analysed.
Freedom
Any mains rated sensor can be easily connected to the DALI line with a zencontrol mains converter.
When connected, the sensor will operate as a fully compliant DALI-2 motion sensor. This flexibility makes it easy to bring in specialised sensors, such as high mounting sensors used in warehouses, long-range sensors or even dual technology sensors.


Value
zencontrol smart drivers and some Ektor emergency products have the added support for mains rated sensors. When a mains-rated sensor is connected to one of these devices, the product is automatically added to the DALI line as a fully compliant DALI-2 sensor, which can be used by the system.
Adding a sensor to a building is simple and easy as it only requires wiring to the closest product containing a zencontrol smart driver or Ektor emergency product.
Partition control
When used with partition control the sensors can automatically change targets and actions.


Multiple profiles
zencontrol supports multiple profiles, which allows the functionality of sensors to change during different periods of the day (e.g. daytime, afterhours, generator, emergency, security walkthrough, cleaners). This ability gives greater flexibility, comfort and control.
Switches
Don’t be left short with limited switching options

Unlimited control
With its practically unlimited control the switches can be configured to preform almost any task. Turn on lights, start sequences or change the operation of the building or even run a report.

Standard
Connect the zc-switch to any standard volt free push-button, matching the lighting control panels to the buildings decor.

Scene set switch plates
Use zencontrols DALI wall plates for any control action including boardroom control and scene selection

Illuminated push-buttons
Use zencontrols illuminated push-buttons in common wall plates for a tactile feel and illuminated feedback
Scene sets
Configure scene recalls from any switch to automatically configure room lighting to set the desired mood or purpose. zencontrol scenes can include dimming of lights for projector screens, DALI fan and blinds along with integration to HVAC and other building services.


Partition Control
Use the zc-switch as a logical input allowing rooms to operate differently depending on their configuration (supporting up to 5 logical inputs per room)
Configurable Panels
Configure your switch panel the way you want it, with different plate colours and button configurations.


Customisable labels
Customise button labels to suit the application, just one of the ways zencontrol makes lighting control easier. Use any of the three sizes of buttons to customise your label onto.
Rotary Control
Use the zc-switch with a rotary encoder to provide users familiar functionality and experiences


Multiple Profiles
zencontrol supports multiple profiles, which allows the functionality of switches to change during different periods of the day (daytime, afterhours, Generator, Emergency, security walkthrough, Cleaners). This ability gives greater flexibility, comfort and control.